Services

Systems which we design, and build, we operate.

What we do

Six services, one partner.

DICIT is a system integrator for data centres. The same team carries a facility from first condition analysis through to continuous operation.

What we deliver

Non-IT infrastructure without compromise.

DICIT VISIO

Modular DCIM monitoring system.

The core tool for monitoring and controlling data center non-IT infrastructure, tracking operational performance and ensuring SLA compliance. Fully modular and scalable, from a small server room to a Tier IV facility spanning 1,000+ m² and hundreds of racks.

Alarms in seconds, 1-second data sampling, and real-time SLA tracking mean problems are caught before they become incidents.

Overview dashboards, energy flow diagrams, technology-focused floor plans, and IT hall graphics, with non-IT equipment control from a single interface.

Track IT and non-IT power consumption down to the rack or server level, monitor PUE and cooling and UPS efficiency, and stay ahead of customer and vendor SLAs.

Standard and custom reports on a robust Microsoft Visual Report Studio foundation.

Give customers their own secure view: power, temperature and humidity (ASHRAE 2010), rack-level consumption, live alarms, SNMP and email notifications, and SLA reporting for their slice of the infrastructure.

Proprietary configuration built on industry-standard SCADA, with redundant hardware and communications, high availability, multi-monitor support, and role-based access control.

CFD analysis

See the airflow before anything is built.

3D simulation of airflow and temperature, used to confirm the cooling design before it is built and to recover wasted cooling capacity in rooms already running.

Airflow and temperature across the room, simulated in three dimensions.

Scenario analysis that shows how the room will behave before it does.

Recommendations that recover wasted cooling and capacity.

What is in the contract

When downtime isn't an option.

24 x7

Hotline and dispatch

Continuous service standby, every day of the year.

2 h

Response

Call back from the moment a fault is reported.

12 h

On site

Arrival for a service intervention, critical and non-critical alike.

24 h

Critical systems

UPS, IT cooling, electrical distribution — where IT operation is down.

48 h

Support systems

Security and fire systems, monitoring.

10 days

Everything else

Generator sets, non-IT cooling, faults with no IT outage.

Preventive inspections

Prevention is the best protection.

Carried out to STN, manufacturer recommendations and internal standards.

Monthly

Fire systems

Fire alarm, early smoke detection, fixed suppression.

Quarterly

Core plant

Cooling, electrical, UPS, generator sets, monitoring, security.

Half-yearly

Air conditioning

Units, mechanics and cooling circuit.

Yearly

All systems

Complete maintenance, plus inspections.

5 years

Electrical

Electrical installation inspection.

10 years

Suppression

Pressure test of suppression pipework.

Why DICIT

Infrastructure operators
cannot afford to lose.

Slovakia's leader in data center infrastructure

We manage a large share of the state's critical systems, the kind that are not allowed to go down. The track record is the proof.

Visionary engineering design

Precision engineering and innovative designs that anticipate future needs, ensuring optimal performance and efficiency for complex data center environments.

Seamless E2E implementation

Comprehensive delivery and management of complex projects from initial design to final commissioning, ensuring full compliance with local regulations and technical standards.

Proactive care & Rapid response

24/7 monitoring and rapid incident response. Prophylaxis to detect anomalies early and prevent downtime, ensuring business continuity.